Book your yearly Baxi boiler service and keep your warranty on track.
Baxi asks for the boiler and its magnetic filter to be serviced every year, within 60 days of your installation anniversary. Our Gas Safe engineers service both, check the system water for sludge, and tell you plainly what they find.
Our engineer works through the following on each visit:
Swipe to compare plans →
Not sure which plan fits? Compare what each one covers below or call 0808 164 2892.
4.7 on Trustpilot from 18,000+ reviews.
Checkatrade’s 2026 cost guide puts a one-off gas boiler service in the UK at £80 to £120, with £100 the average. PlusHeat covers your yearly Baxi service at £6.98 a month, which totals £83.76 annually.
Yes. Baxi asks for the boiler and filter to be serviced every year, within 60 days of your installation anniversary, by a Gas Safe registered engineer, and for the engineer to check the system water is clean and free of sludge. Ours are Gas Safe registered and do both.
Keep the record we leave you. If Baxi’s own service division didn’t carry out the service, Baxi can ask you to prove it happened. Miss the annual service, the 30-day registration or the installer’s Benchmark checklist and the warranty reverts to one year. On the 800 range, the supplied Adey filter also has to be fitted, registered and kept in place, or the 10-year cover drops to two.
Baxi says that codes such as E23, E53, E119, E128 and E133, after the boiler has shut down, may indicate that the condensate pipe has frozen. Their advice is to switch the boiler off, then warm the frozen section of pipe with a hot water bottle, a heat pack or warm (not boiling) water, and restart. If the code still remains, call an engineer.
Common causes for pressure fall are leaks in the system, a faulty pressure relief valve, or trapped air. Our engineer checks for each of these during the service.
Our Baxi gas boiler service covers combi, system and heat-only models, from the current 800 and 600 ranges back through older Duo-tec and Platinum boilers. Our engineers also work on Vaillant, Glow-worm, Ideal and Worcester Bosch models.
The same eight checks as any Baxi service, with a few things the engineer looks at more closely on a combi. Hot water comes straight off the mains through a plate heat exchanger, so that’s where scale shows up first and where a weak flow or a shower that runs hot then cold usually starts. The engineer also checks system pressure, which drifts more noticeably on a combi than on a system boiler with a cylinder.